• Steam Spray Autoclave Sterilizer Retort

Steam Spray Autoclave Sterilizer Retort

Process: Thermal Processing
Power Source: Steam
Automatic Grade: Semi-Automatic
Application: Canned Food
Customized: Customized
Working Pressure of Autoclave: 0.3mpa
Customization:
Diamond Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GT7C 1200
Designed Pressure of Autoclave
0.35mpa
Design Temperature
147 Degree C
Working Temperature
121 Degree C
Usage
Canned Food, Glass Jar, Pouch
Transport Package
Wooden Case
Origin
Wenzhou China

Product Description

Steam Spray Autoclave sterilizer retort
1. Batch Sterilizers Steam / Water Spray sterilizer retort
2. Top shower for cans and glass PLUS side spray for pouches and trays
Batch Sterilizers Steam / Water Spray sterilizer retort steam retort sterilizer autoclave

Water spray system working principle:
1. Water filling
Prior to the start of the process, the retort is filled with a small volume of
Process water (approx. 27 gallons/basket) such that the water level is below
The bottom of the baskets. This water can be used for successive cycles if
Desired, as it is sterilized with each cycle.

2. Heating
Once the cycle is begins, the steam valve opens and the circulation pump is
Switched on. The mixture of steam and water spraying from the top and the
Sides of the retort vessel creates highly turbulent convection currents that
Rapidly homogenizes the temperature at every point in the retort and
Between the containers

3. Sterilization
Once the programmed sterilization temperature has been reached, it is held
For the programmed time within +/- 1º F. Similarly, the pressure is kept
Within +/-1 psi by adding and venting compressed air as needed.

4. Cooling
At the end of the sterilization step, the retort switches into cooling mode. As
The process water continues to be circulated through the system, a portion of
It is diverted through one side of a plate heat exchanger. At the same time,
Cold water passes through the other side of the plate heat exchanger. This
Results in the process water inside the retort chamber being cooled in a
Controlled fashion.

5. End
Once the retort is cooled to the programmed temperature setpoint, the cold
Water inlet valve on the heat exchanger closes and the pressure inside the
Retort is automatically relieved. The water level is lowered from the
Maximum down to the medium level. The door is equipped with a safety
Locking device which prevents the opening of the door in the case of residual
Steam Spray Autoclave Sterilizer Retort
Wenzhou Wanyuan Food Mechanical Factory- - Autoclave sterilizer retort
Steam Spray Autoclave sterilizer retort
Here below the autocalve sterilizer retort specification:
Model GT7C 720  GT7C 1200 GT7C 2000  GT7C 2400
Category Elementary Pressure Vessel
Internal Diameter (mm) 900 1000 1100 1200
Volume( m³) 1.2 2 3.5 4.2
Design Temperature 143 degree C
Working Temperature 123 degree C
Design Pressure 0.3 MPa
Working Pressure 0.15 MPa
Working Medium water\steam\compressed air
Main Pressure Part Material SS304
Welding Coefficient 0.7
Corrosion Allowance 1mm
Net Weight(kg) 600 1100 1700 2000
External Dimensions(mm) length 2100 2800 3700 4000
Width 1300 1450 1600 1600
height 1650 1700 1800 1900

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now